Transformers - Current Sense Transformers

 
6RL-101: Current Transformer, 100:5, 100 A, 50 Hz, 400 Hz, Panel
Application With Ammeters, wattmeters, and cross current compensation. Insulation Level 0.6kV, 10kV BIL full wave· Flexible leads are 1015 105°C, CSA approved #16 AWG, 24" long· Non-standard lengthy to be specified·

6RL-102: Current Transformer, 1000:5, 1 Ka, 50 Hz, 400 Hz, Panel
6RL-122: Current Transformer, 1200:5, 1.2 Ka, 50 Hz, 400 Hz, Panel
6RL-151: Current Transformer, 150:5, 150 A, 50 Hz, 400 Hz, Panel
6RL-201: Current Transformer, 200:5, 200 A, 50 Hz, 400 Hz, Panel
6RL-301: Current Transformer, 300:5, 300 A, 50 Hz, 400 Hz, Panel
6RL-401: Current Transformer, 400:5, 400 A, 50 Hz, 400 Hz, Panel
6RL-501: Current Transformer, 500:5, 500 A, 50 Hz, 400 Hz, Panel
6RL-601: Current Transformer, 600:5, 600 A, 50 Hz, 400 Hz, Panel
6RL-751: Current Transformer, 750:5, 750 A, 50 Hz, 400 Hz, Panel
6RL-801: Current Transformer, 800:5, 800 A, 50 Hz, 400 Hz, Panel
CT-1025: Trans Curr Sense 1:1000 25a
Ratio Correction factor (RCF*) (Multiply current reading by this factor to compensate for transformer losses) OUTPUT RESPONSE vs INPUT CURRENT @ RATED BURDEN : RATIO ERROR vs RATED BURDEN @ INPUT CURRENT
HM31-31300LF: Encapsulated Current Sense Trans
HM31 ; 1 150 150 ; 48mH ; 20A ; 11 Ohm Max ; 1000V
P0581NL: Xfrmr Curr Sense 76mh 200:1:1 Th
UL/C-UL recognized components 3000Vrms gate to drive winding test Useful operating frequency from to 500 kHz Most popular winding configurations Notes: 1. These current sense transformers have two one turn

P0582NL: Xfrmr Curr Sense 19mh 100:1:1 Th
P0583NL: Xfrmr Curr Sense 5mh 50:1:1 T/h
HM31-30100LF: Encapsulated Current Sense Trans
HM31 ; 1 100 ; 20mH ; 20A ; 1.4 Ohm Max ; 660V µS ; Mounting
AC-1005: Current Sensing Transformer, Metering, 1ct:1ct, 5 A, Through Hole
Applications· Sensing Overload Current· Ground fault detection· Metering· Analog to Digital Circuits Notes: 1) Unless requested, the terminating resistor and the one-turn primary are not supplied 2) Pin 3: Normally
ACX-1075: Xfmr 50/60hz Pcb 1% 2500:1 75a
ACX
5RL-101: Current Transformer, 100:5, 100 A, 50 Hz, 400 Hz, Panel
**NOTE: When ordering, prefix Catalogue Number with model designation required, i.e. 5SFT­500, 5RL­500, etc. Application: With ammeters, wattmeters and cross current compensation. Insulation Level: 600 Volts,

5RL-102: Current Transformer, 1000:5, 1 Ka, 50 Hz, 400 Hz, Panel
5RL-122: Current Transformer, 1200:5, 1.2 Ka, 50 Hz, 400 Hz, Panel
5RL-201: Current Transformer, 200:5, 200 A, 50 Hz, 400 Hz, Panel
5RL-251: Current Transformer, 250:5, 250 A, 50 Hz, 400 Hz, Panel
5RL-301: Current Transformer, 300:5, 300 A, 50 Hz, 400 Hz, Panel
5RL-401: Current Transformer, 400:5, 400 A, 50 Hz, 400 Hz, Panel
5RL-500: Current Transformer, 50:5, 50 A, 50 Hz, 400 Hz, Panel
5RL-501: Current Transformer, 500:5, 500 A, 50 Hz, 400 Hz, Panel
5RL-601: Current Transformer, 600:5, 600 A, 50 Hz, 400 Hz, Panel
5RL-750: Current Transformer, 75:5, 75 A, 50 Hz, 400 Hz, Panel
CT-1015: Trans Curr Sense 1:1000 15a
Ratio Correction factor (RCF*) (Multiply current reading by this factor to compensate for transformer losses) OUTPUT RESPONSE vs INPUT CURRENT @ RATED BURDEN : RATIO ERROR vs RATED BURDEN @ INPUT CURRENT
CR8448-2000-F: Transformer Current Hi Frequency
CR8400 ; 20kHz ~ 200kHz ; 50A ; 90 Ohm ; Free Hanging (In-Line) ;
56SFT-122: Current Transformer, 1200:5, 1.2 Ka, 50 Hz, 400 Hz, Panel
**NOTE: When ordering, prefix Catalogue Number with model designation required, i.e. ­ 101. Application With ammeters, wallmeters and cross current compensation. Insulation Level 0.6kV, 10kV full wave·

56SFT-151: Current Transformer, 150:5, 150 A, 50 Hz, 400 Hz, Panel
56SFT-201: Current Transformer, 200:5, 200 A, 50 Hz, 400 Hz, Panel
56SFT-251: Current Transformer, 250:5, 250 A, 50 Hz, 400 Hz, Panel
56SFT-301: Current Transformer, 300:5, 300 A, 50 Hz, 400 Hz, Panel
56SFT-401: Current Transformer, 400:5, 400 A, 50 Hz, 400 Hz, Panel
56SFT-500: Current Transformer, 50:5, 50 A, 50 Hz, 400 Hz, Panel
56SFT-501: Current Transformer, 500:5, 500 A, 50 Hz, 400 Hz, Panel
56SFT-601: Current Transformer, 600:5, 600 A, 50 Hz, 400 Hz, Panel
56SFT-750: Current Transformer, 75:5, 75 A, 50 Hz, 400 Hz, Panel
56SFT-751: Current Transformer, 750:5, 750 A, 50 Hz, 400 Hz, Panel
AZ-0750: Xfmr 50/60hz Fl 750:1 40a
AZ
CT-1040: Trans Curr Sense 1:1000 40a
Ratio Correction factor (RCF*) = 1.026@10% (Multiply current reading by this factor to compensate for transformer losses) OUTPUT RESPONSE vs INPUT CURRENT @ RATED BURDEN : RATIO ERROR vs RATED BURDEN @ INPUT
TT 100-SD: Transform Curr 100a Split Core
Split core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). IPN Primary nominal current
AC1005: Transformer Current 5.0 Amp
Applications· Sensing Overload Current· Ground fault detection· Metering· Analog to Digital Circuits Notes: 1) Unless requested, the terminating resistor and the one-turn primary are not supplied 2) Pin 3: Normally
AX-1000: Xfmr 50/60hz Pcb 1000:1 10a
AX
AL-101: Current Transformer, 100:5, 50 Hz, 400 Hz, Panel
APPLICATION: With ammeters, energy management systems, and instrumentation. CATALOG CURRENT ACCURACY BURDEN NUMBER RATIO 60 Hz

AL-151: Current Transformer, 150:5, 150 A, 50 Hz, 400 Hz, Panel
AL-201: Current Transformer, 200:5, 200 A, 50 Hz, 400 Hz, Panel
AL-251: Current Transformer, 250:5, 250 A, 50 Hz, 400 Hz, Panel
AL-301: Current Transformer, 300:5, 300 A, 50 Hz, 400 Hz, Panel
AL-401: Current Transformer, 400:5, 400 A, 50 Hz, 400 Hz, Panel
AL-600: Current Transformer, 60:5, 60 A, 50 Hz, 400 Hz, Panel
AL-750: Current Transformer, 75:5, 75 A, 50 Hz, 400 Hz, Panel
CST-1025: Sense Xfmr Primary 25a
Triad current sense transformers are used to detect the current passing through a conductor. These transformers are very reliable and operate efficiently at 50/60 Hz. RoHS Compliance: As of manufacturing

CST-1025-B: Sense Transformer Primary 25a
PB0025NL: Xfrmr Curr Sense 1.4mh 50:1 Smd
Height: 10mm Max Footprint: x 15.0mm Max Frequency Range: to 500kHz Current Rating: to 35A Notes: 1. The temperature of the component (ambient temperature plus temperature rise) must be within the specified

PB0025NLT
PB0026NL: Xfrmr Curr Sense 5.6mh 100:1 Smd
PB0026NLT
PB0027: Current Sense Transformer 200:1
PB0027NL: Xfrm Curr Sense 22.4mh 200:1 Smd
PB0027NLT
HM31-10100LF: Encapsulated Current Sense Trans
HM31 ; 1 100 ; 20mH ; 5A ; 1.4 Ohm Max ; 600V µS ; Mounting
120-162: Current Transformer, 1600:5, 1.6 Ka, 50 Hz, 400 Hz, Panel
1600 5 ; 1.6kA ; 50Hz ; 400Hz ; Panel
2277116: Plug-in Xfrmr 250a 5va
CST206-3T: Current Sensing Transformer, High Frequency, 300ct, 130 Mh, 70 A, Through Hole
Description: Designed for switching power supply applications, Triad current sense transformers are used to detect the current passing through a conductor. These transformers are very reliable and operate

CST206-3T-B: Transf 130mh Ctap Crnt Sense
749251070: Current Sensing Transformer, 1:70, 2.2 Ohm, 980 H, 35 V S, 10 A, Surface Mount
Properties Inductance Rated current DC Resistance 1 DC Resistance 2 Turns ratio Voltage-µSecond Rated voltage Insulation test voltage It is recommended that the temperature of the part does not exceed
CR3110-3000-72: Transformer Current Split Core
2RL-101: Current Transformer, 100:5, 100 A, 50 Hz, 400 Hz, Panel
CSA approved #16 AWG, 24" long· Non-standard length to be specified· Terminals are brass studs No. 8-32 UNC with one flat washer, lockwasher and regular nut· SHT and SFT case styles also available as SHL and SFL with

2RL-121: Current Transformer, 120:5, 120 A, 50 Hz, 400 Hz, Panel
2RL-1250: Current Transformer, 125:5, 125 A, 50 Hz, 400 Hz, Panel
2RL-151: Current Transformer, 150:5, 150 A, 50 Hz, 400 Hz, Panel
2RL-201: Current Transformer, 200:5, 200 A, 50 Hz, 400 Hz, Panel
2RL-251: Current Transformer, 250:5, 250 A, 50 Hz, 400 Hz, Panel
2RL-301: Current Transformer, 300:5, 300 A, 50 Hz, 400 Hz, Panel
2RL-401: Current Transformer, 400:5, 400 A, 50 Hz, 400 Hz, Panel
2RL-500: Current Transformer, 50:5, 50 A, 50 Hz, 400 Hz, Panel
2RL-600: Current Transformer, 60:5, 60 A, 50 Hz, 400 Hz, Panel
2RL-750: Current Transformer, 75:5, 75 A, 50 Hz, 400 Hz, Panel
CT200A: Transformer Toroid 2va 200:5
CT ; 200 5 ; 5A ; Chassis Mount ; 98.30mm Dia x 44.45mm W ; Height
FIS101NL: Choke Npb
Current sense inductors, as feedback elements linking the output and pulse control circuitry, allow low-cost regulation of switchmode power supplies Fully encapsulated with a frequency of 200 kHz maximum

FIS111NL: Xfrmr Curr Sense 15a 1:100 T/h
FIS121NL: Xfrmr Curr Sense 15a 1:200 T/h
CST206-1A: Current Sensing Transformer, High Frequency, 100, 14 Mh, 110 A, Through Hole
Description: Designed for switching power supply applications, Triad current sense transformers are used to detect the current passing through a conductor. These transformers are very reliable and operate

CST206-1A-B: Transf 14mh Crnt Sense
19SHT-102: Current Transformer, 1000:5, 1 Ka, 50 Hz, 400 Hz, Panel
ANSI Metering class at 60Hz Secondary winding resistance **NOTE: When ordering, prefix catalogue number with model designation required, i.e. ­ 301, etc. Application: With ammeters, wattmeters and cross

19SHT-122: Current Transformer, 1200:5, 1.2 Ka, 50 Hz, 400 Hz, Panel
19SHT-152: Current Transformer, 1500:5, 1.5 Ka, 50 Hz, 400 Hz, Panel
19SHT-162: Current Transformer, 1600:5, 1.6 Ka, 50 Hz, 400 Hz, Panel
19SHT-202: Current Transformer, 2000:5, 2 Ka, 50 Hz, 400 Hz, Panel
19SHT-252: Current Transformer, 2500:5, 2.5 Ka, 50 Hz, 400 Hz, Panel
19SHT-301: Current Transformer, 300:5, 300 A, 50 Hz, 400 Hz, Panel
19SHT-302: Current Transformer, 3000:5, 3 Ka, 50 Hz, 400 Hz, Panel
19SHT-401: Current Transformer, 400:5, 400 A, 50 Hz, 400 Hz, Panel
19SHT-501: Current Transformer, 500:5, 500 A, 50 Hz, 400 Hz, Panel
19SHT-601: Current Transformer, 600:5, 600 A, 50 Hz, 400 Hz, Panel
6SFT-201: Current Transformer, 200:5, 200 A, 50 Hz, 400 Hz, Panel
APPLICATION: With ammeters, wattmeters, and cross current compensation. FREQUENCY: 50-400 Hz. INSULATION LEVEL: 600 Volts, 10 kV BIL full wave. Flexible leads are 1015, 105 C., CSA approved. #16 AWG, 24" long.
CTWH3-60-T100-300: Current Transformer, 30:5, 30 A, 50 Hz, 400 Hz, Panel
MMeeddiiuumm VVoollttaaggee CCuurrrreenntt TTrraannssffoorrmmeerr Model CTWH3-60-T100 Wound Primary CT Primary terminals are plated copper bars. See chart next page for sizes. Secondary terminals are brass
AC1200: Transformer Current 200 Amp
Applications· Sensing Overload Current· Ground fault detection· Metering· Analog to Digital Circuits Notes: 1) Unless requested, the terminating resistor and the one-turn primary are not supplied 2) Pin 3: Normally
PA1005.050NL: Xfmr,current Sense 1:50 Npb
Height: 5.5mm Max Footprint: x 7.2mm Max Current Rating:up to 20A Frequency Range: to 1MHz Low Primary DCR version of P820X 1.The temperature of component (ambient temperature plus temper-ature rise) must

PA1005.050NLT: Xfrmr Curr Sense 0.50mh 1:50 Smd
PA1005.070NL: Xfmr,current Sense 1:70 Npb
PA1005.070NLT: Xfrmr Curr Sense 0.98mh 1:70 Smd
PA1005.100NL: Xfmr,current Sense 1:100 Npb
PA1005.100NLT: Xfrmr Curr Sense 2.0mh 1:100 Smd
PA1005.125NL: Xfmr,current Sense 1:125 Npb
2276256: Xfrmr Plug-in 400a 7.5va
CR170SHT-402: Current Trans Square 4000a
Applications Ammeters Energy Measurement Watt/VAR/Watthour Measurement RL SFT Current Sensing Relays Features Low Cost Core Secured via Epoxy Resin Hand Tuned Accuracy SFL SHT Common Ratios in Stock Regulatory

CR2DARL-101: Xformer Ansi Metering Current Rl
CR2DARL-151
CR2DARL-301
CR2DARL-500: Transformr Ansi Metering Current
CR2RL-101: Transformr Commercial Current Rl
CR2RL-151
CR2RL-201
CR2RL-301
CR2RL-500
CR2RL-800
101990029: Non-invasive Ac Current Sensor (
SPECIFICATION Customer Title XiDi Technology Manufacture Model SCT-013-000 Charateristicsopen size:13mm×13mm 1m leading wire Core material:Ferrite Fire resistance property:in accordance with UL 94-V0 Dielectric
749251125: Current Sensing Transformer, 1:125, 6.5 Ohm, 3 Mh, 68 V S, 10 A, Surface Mount
Properties Inductance Rated current DC Resistance 1 DC Resistance 2 Turns ratio Voltage-µSecond Rated voltage Insulation test voltage It is recommended that the temperature of the part does not exceed
56050C: Current Sensing Transformer, 1:50, 0.199 Ohm, 5 Mh, 10 A, Through Hole
FEATURES RoHS compliant Turn variants Primary current rating 10A The 5600 series of current sense transformers are designed to monitor AC currents. They can be used for high frequency current sensing,

56100C: Current Sensing Transformer, 100, 1.4 Ohm, 30 Mh, 10 A, Through Hole
56200C: Current Sensing Transformer, 1:200, 80 Mh, 10 A, Through Hole
56300C: Current Sensing Transformer, 300, 8.59 Ohm, 180 Mh, 10 A, Through Hole
56T100C: Current Sensing Transformer, 100:1, 20 Mh, 10 A, Through Hole
56T200C: Current Sensing Transformer, 200ct, 2.81 Ohm, 80 Mh, 10 A, Through Hole
56T300C: Current Sensing Transformer, 300ct, 8.59 Ohm, 180 Mh, 10 A, Through Hole
2276641: Bus-bar Xfrmr
The transformer quick-action mechanism enables the lightning-fast mounting of PACT current transformers on the power rail. The installation can be completed easily by hand without the use of tools. Fixing
2277035: Bus-bar Xfrmr
Bus-bar current transformer, A AC primary current; A AC secondary current; accuracy class 5 VA rated power Packing unit Weight per Piece (excluding packing) Custom tariff number Country of origin Primary
15RL-500: Current Transformer, 50:5, 50 A, 50 Hz, 400 Hz, Panel
APPLICATION: With ammeters, energy management systems, and instrumentation. Terminals are brass studs No. 8-32 with one flatwasher, lockwasher and regular nut. Flexible leads are 1015 105oC CSA approved.

16RBL-151: Current Transformer, 150:5, 150 A, 50 Hz, 400 Hz, Panel
55050C: Current Transformer, 1:1:50, 15 A, 50 Khz, 500 Khz, Surface Mount
FEATURES RoHS compliant Primary current rating 15A4 turn variants Primary to secondary isolation 1000Vrms 50kHz-500kHz frequency range Surface mount Industry-standard footprint UL94 V-0 package materials

55050C-R: Xfrmr Curr Sense 15a 1:1:50 Smd
55100C: Current Transformer, 1:1:100, 15 A, 50 Khz, 500 Khz, Surface Mount
55100C-R: Xfrmr Curr Sense 15a 1:1:100 Smd
55200C: Current Transformer, 1:1:200, 15 A, 50 Khz, 500 Khz, Surface Mount
55200C-R: Xfrmr Curr Sense 15a 1:1:200 Smd
HM31-30300LF: Encapsulated Current Sense Trans
HM31 ; 1 300 ; 195mH ; 20A ; 11 Ohm Max ; 2000V µS ; Mounting
AZ-1000: Xfmr 50/60hz Fl 1000:1 50a
AZ
53020C: Current Transformer, 1:20, 10 A, 50 Khz, 500 Khz, Surface Mount
FEATURES RoHS compliant Primary current rating to 200 turn variants Primary to secondary isolation 500Vrms 50kHz-500kHz frequency range Surface mount Industry-standard footprint UL94 V-0 package materials

53030C: Current Transformer, 1:30, 10 A, 50 Khz, 500 Khz, Surface Mount
53040C: Current Transformer, 1:40, 10 A, 50 Khz, 500 Khz, Surface Mount
53050C: Current Transformer, 1:50, 10 A, 50 Khz, 500 Khz, Surface Mount
53060C: Xfrmr Curr Sense 10a 1:60 Smd
53070C: Xfrmr Curr Sense 10a 1:70 Smd
53100C: Current Transformer, 1:100, 10 A, 50 Khz, 500 Khz, Surface Mount
53125C: Xfrmr Curr Sense 10a 1:125 Smd
53150C: Xfrmr Curr Sense 10a 1:150 Smd
53200C: Current Transformer, 1:200, 10 A, 50 Khz, 500 Khz, Surface Mount
CR8450-2000: Transformer Current General Purp
CR8400 ; 20Hz ~ 1kHz ; 200A ; 73 Ohm ; Free Hanging (In-Line) ;
7RL-101: Current Transformer, 100:5, 100 A, 50 Hz, 400 Hz, Panel
**NOTE: When ordering, prefix Catalogue Number with model designation required, i.e. ­ 500, etc. Application: With ammeters, wattmeters and cross current compensation. Insulation Level: 600 Volts, 10kV

7RL-102: Current Transformer, 1000:5, 1 Ka, 50 Hz, 400 Hz, Panel
7RL-122: Current Transformer, 1200:5, 1.2 Ka, 50 Hz, 400 Hz, Panel
7RL-152: Current Transformer, 1500:5, 1.5 Ka, 50 Hz, 400 Hz, Panel
7RL-162: Current Transformer, 1600:5, 1.6 Ka, 50 Hz, 400 Hz, Panel
7RL-251: Current Transformer, 250:5, 250 A, 50 Hz, 400 Hz, Panel
7RL-301: Current Transformer, 300:5, 300 A, 50 Hz, 400 Hz, Panel
7RL-401: Current Transformer, 400:5, 400 A, 50 Hz, 400 Hz, Panel
7RL-601: Current Transformer, 600:5, 600 A, 50 Hz, 400 Hz, Panel
7RL-751: Current Transformer, 750:5, 750 A, 50 Hz, 400 Hz, Panel
7RL-801: Current Transformer, 800:5, 800 A, 50 Hz, 400 Hz, Panel
2277653: Bus-bar Current Transformr 10va
Window-type current transformer, A AC primary current; A AC secondary current; accuracy class 10 VA rated power Packing unit Weight per Piece (excluding packing) Custom tariff number Country of origin Primary
B82801C1265A150: Transf Current Sense 12.6mh Smd
¤EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Application

B82801C145A50: Transf Current Sense 1.4mh Smd
B82801C2245A200: Transf Current Sense 22.4mh Smd
B82801C565A100: Transf Current Sense 5.6mh Smd
2277815: Transformer
Window-type current transformer, A AC primary current; A AC secondary current; accuracy class 1.25 VA rated power Packing unit Weight per Piece (excluding packing) Custom tariff number Country of origin Primary
2277145: Bus-bar Xfrmr
Window-type current transformer, A AC primary current; A AC secondary current; accuracy class 10 VA rated power Packing unit Weight per Piece (excluding packing) Custom tariff number Country of origin Primary
PE-68210T: Transformer
1. The temperature of the component (ambient temperature plus temperature rise) must be within the specified operating temperature range. 2.The maximum current rating is based upon temperature rise of the component

PE-68280
2277239: Bus-bar Xfrmr
Window-type current transformer, A AC primary current; A AC secondary current; accuracy class 10 VA rated power Primary rated current Ipn: 2500) A Circular conductor dimensions: 53 mm Rail dimensions:
CT1000A: Transformer Toroid 5-50va 1000:5
Features Toroidal design. Supplied with 24" insulated secondary leads, terminated with crimped ring connectors. Suitable for use with bare (uninsulated) primary conductor in circuits KV Hi pot); or at higher

CT100A: Transformer Toroid 2va 100:5
CT1200A: Transformr Toroid 10-50va 1200:5
CT150A: Transformer Toroid 2va 15:5
CT250A: Transformer Toroid 2-5va 25:5
CT300A: Transformer Toroid 2-10va 300:5
CT400A: Transformer Toroid 2-10va 400:5
CT500A: Transformer Toroid 2-20va 500:5
CT50A: Transformer Toroid 2va 50:5
CT600A: Current Transformer, Indoor, 600:5, Chassis
CT60A: Transformer Toroid 2va 60:5
2277637: Bus-bar Xfrmr
Window-type current transformer, A AC primary current; A AC secondary current; accuracy class 5 VA rated power Packing unit Weight per Piece (excluding packing) Custom tariff number Country of origin Primary
H1300FNL: 10/100 Transformer 1.41:1. / 1.4

H1300FNLT
CR8420-100: Transformer General Purpose
CR8400 ; 1 100 ; 20Hz ~ 1kHz ; Free Hanging (In-Line) ; 30.00mm
101990065: Ac Current Sensor 70a Max
CTD1X1005AXXX: Current Transformer, 100 A, 48 Hz, 62 Hz, Din Rail, Panel
Accessories AC Current Transformer (max 23mm cable) Type CTD-1X · Cable and bus-bar type current transformer· 0.5 class, currents from 300 A· Removable DIN-rail mounting holder· Removable panel fixing
HM31-20050LF: Encapsulated Current Sense Trans
HM31 ; 1 50 ; 5mH ; 20A ; 700 mOhm Max ; 330V µS ; Mounting
56RBT-101: Current Transformer, 100:5, 100 A, 50 Hz, 400 Hz, Panel
APPLICATION: With ammeters, wattmeters, and cross current compensation. FREQUENCY: 50-400 Hz. INSULATION LEVEL: 600 Volts, 10 kV BIL full wave. Flexible leads are 1015, 105 C., CSA approved. #16 AWG, 24" long.

56RL-102-1: Current Transformer, 1000:5, 1 Ka, 50 Hz, 400 Hz, Panel
56RL-201: Current Transformer, 200:5, 200 A, 50 Hz, 400 Hz, Panel
56RL-501: Current Transformer, 500:5, 500 A, 50 Hz, 400 Hz, Panel
56RL-601: Current Transformer, 600:5, 50 Hz, 400 Hz, Panel
56RL301-1: Current Transformer, 300:5, 300 A, 50 Hz, 400 Hz, Panel
AC-1030: Current Sensing Transformer, Metering, 1ct:1ct, 30 A, Through Hole
1CT 1CT ; 30A ; Through Hole

AC-1050: Current Sensing Transformer, Metering, 1ct:1ct, 50 A, Through Hole
AC-1060: Current Sensing Transformer, Metering, 1ct:1ct, 60 A, Through Hole
AC-1100: Current Sensing Transformer, Metering, 1ct:1ct, 100 A, Through Hole
AC-1150: Current Sensing Transformer, Metering, 1ct:1ct, 150 A, Through Hole
AC-1200: Current Sensing Transformer, Metering, 1ct:1ct, 200 A, Through Hole
2276133: Pact Mcr-v2-5012- 85- 250-5a-1
CR8350-2500-N3: Transf. Curr. Trimmed Leads
CT800A: Transformer Toroid 5-50va 800:5
CT ; 800 5 ; 5A ; Chassis Mount ; 130.05mm Dia x 44.45mm W ; Height
101990062: Ac Current Sensor 25a Max
CT160-5-F7: Current Transformer, 2:1, 10 A, Chassis
16 SERIES (Type 160) MOULDED CASE CURRENT TRANSFORMERS WOUND PRIMARY RANGE DESCRIPTION A range of compact low cost moulded case current transformers suitable for primary currents from to 50A with built

CT160-5-H7: Current Transformer, 4:1, 20 A, Chassis
2277129: Bus-bar Xfrmr
Window-type current transformer, A AC primary current; A AC secondary current; accuracy class 7.5 VA rated power Packing unit Weight per Piece (excluding packing) Custom tariff number Country of origin Primary
AC1040: Transformer Current 40.0 Amp
Applications· Sensing Overload Current· Ground fault detection· Metering· Analog to Digital Circuits Notes: 1) Unless requested, the terminating resistor and the one-turn primary are not supplied 2) Pin 3: Normally
PE-67050: Transformer
Meet IEC950 insulation requirements 4250VRMS primary to secondary breakdown voltage Notes: 1. These current sense transformers have a 1 turn primary winding, secondary turns (Ns) as indicated in the table,

PE-67050NL: Xfrmr Curr Sense 35a 5.0mh T/h
PE-67100: Transformer
PE-67100NL: Xfrmr Curr Sense 37a 20mh T/h
PE-67200: Transformer
PE-67200NL: Xfrmr Curr Sense 38a 80mh T/h
PE-67300NL: Xfrmr Curr Sense 37a 180mh T/h
CR8420-1000-PCB: Trans Current Pc Pin
CR8400 ; 1 1000 ; 20Hz ~ 1kHz ; Free Hanging (In-Line) ; 30.00mm
CST206-3A: Current Sensing Transformer, High Frequency, 300, 130 Mh, 70 A, Through Hole
Description: Designed for switching power supply applications, Triad current sense transformers are used to detect the current passing through a conductor. These transformers are very reliable and operate

CST206-3A-B: Transf 130mh Crnt Sense
7SHT-801: Current Transformer, 800:5, 800 A, 50 Hz, 400 Hz, Panel
**NOTE: When ordering, prefix Catalogue Number with model designation required, i.e. ­ 500, etc. Application: With ammeters, wattmeters and cross current compensation. Insulation Level: 600 Volts, 10kV
H1300NL: 10/100 Transformer 1.41:1. / 1.4

H1300NLT
CR8420-1000-G: Transformer Ground Fault Wire Ld
CR8400 ; 1 1000 ; 20Hz ~ 1kHz ; 20A ; 44 Ohm ;
A82-20100: Current Transformer, True Rms, 100 A, 40 Hz, 1 Khz, Panel
Monitoring Relays True RMS AC Current Transformer Types A 82-30 True RMS AC current metering transformer for or 500 AAC. Output current in accordance with IEC 82-20) or output voltage in accordance with

A82-2025: Current Transformer, True Rms, 25 A, 40 Hz, 1 Khz, Panel
A82-20250: Current Transformer, True Rms, 250 A, 40 Hz, 1 Khz, Panel
A82-2050: Current Transformer, True Rms, 50 A, 40 Hz, 1 Khz, Panel
A82-20500: Current Transformer, True Rms, 500 A, 40 Hz, 1 Khz, Panel
CT-1200: Trans Curr Sense 1:1000 200a
Ratio Correction factor (RCF*) = 1.002@10% (Multiply current reading by this factor to compensate for transformer losses) All dimensions are in mm Linear dimensional tolerance ±0.2mm Note : Un-Used pin #3 OUTPUT
CR8449-2000-F: Transformer Current Hi Frequency
CR8400 ; 20kHz ~ 200kHz ; 75A ; 109 Ohm ; Free Hanging (In-Line) ;
HM31-21050LF: Encapsulated Current Sense Trans
HM31 ; 1 25 25 ; 1.3mH ; 20A ; 700 mOhm Max ; 150V