Details, datasheet, quote on part number:100302MW8
| |
| Part: | 100302MW8 |
| Category: | Logic => Military/Aerospace->ECL |
| Description: | 100302 - Low Power Quint 2-Input Or/nOR GATE, Package: Cerquad, Pin Nb=24 |
| Company: | National Semiconductor Corporation |
| Datasheet: | Download 100302MW8 datasheet File size : 110 kB |
| Request For quote: | Find where to buy 100302MW8
|
| |
Datasheet text preview:
100302 Low Power Quint 2-Input OR/NOR Gate
August 1998
100302 Low Power Quint 2-Input OR/NOR Gate
General Description
The 100302 is a monolithic quint 2-input OR/NOR gate with common enable. All inputs have 50 k pull-down resistors and all outputs are buffered. n n n n 2000V ESD protection Pin/function compatible with 100102 Voltage compensated operating range = -4.2V to -5.7V Standard Microcircuit Drawing (SMD) 5962-9152802
Features
n 43% power reduction of the 100102
Logic Symbol
E
Pin Names Dna Dne Oa Oe Oa Oe Data Inputs
Description Enable Input Data Outputs Complementary Data Outputs
Truth Table
D1X L L L
DS100303-1
D2X L L H H L L H H
E L H L H L H L H
OX L H H H H H H H
OX H L L L L L L L
L H H H H
H = HIGH Voltage Level L = LOW Voltage Level
© 1998 National Semiconductor Corporation
DS100303
www.national.com
Connection Diagrams
24-Pin DIP 24-Pin Quad Cerpak
DS100303-3 DS100303-2
www.national.com
2
Absolute Maximum Ratings (Note 1)
If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications. Above which the useful life may be impaired -65°C to +150°C Storage Temperature (TSTG) Maximum Junction Temperature (TJ) Ceramic +175°C VEE Pin Potential to Ground Pin -7.0V to +0.5V Input Voltage (DC) VEE to +0.5V Output Current (DC Output HIGH) -50 mA
ESD (Note 2)
2000V
Recommended Operating Conditions
Case Temperature (TC) Military Supply Voltage (VEE) -55°C to +125°C -5.7V to -4.2V
Note 1: Absolute maximum ratings are those values beyond which the device may be damaged or have its useful life impaired. Functional operation under these conditions is not implied. Note 2: ESD testing conforms to MIL-STD-883, Method 3015.
Military Version DC Electrical Characteristics
VEE = -4.2V to -5.7V, VCC = VCCA = GND, TC = -55°C to +125°C (Note 5) Symbol VOH VOL VOHC VOLC VIH VIL IIL IIH IEE Parameter Output HIGH Voltage Output LOW Voltage Output HIGH Voltage Output LOW Voltage Input HIGH Voltage Input LOW Voltage Input LOW Current Input HIGH Current Power Supply Current -48 -1165 Min -1025 -1085 Max -870 -870 Units mV mV mV mV mV mV -1610 -1555 -870 mV mV mV mV µA 240 340 -17 µA µA mA TC 0°C to +125°C -55°C 0°C to +125°C -55°C 0°C to +125°C -55°C 0°C to +125°C -55°C -55°C to +125°C -55°C to +125°C -55°C to +125°C 0°C to +125°C -55°C -55°C to +125°C Guaranteed HIGH Signal for All Inputs -1830 -1475 0.50 Guaranteed LOW Signal for All Inputs VEE = -4.2V VIN = VIH (Max) VEE = -5.7V VIN = VIL(Min) Inputs Open (Notes 3, 4, 5, 6) (Notes 3, 4, 5, 6) (Notes 3, 4, 5) (Notes 3, 4, 5) (Notes 3, 4, 5, 6) VIN = VIH(Max) or VIL (Min) Loading with 50 to -2.0V (Notes 3, 4, 5) VIN = VIH(Max) or VIL (Min) Loading with 50 to -2.0V (Notes 3, 4, 5) Conditions Notes
-1830 -1620 -1830 -1555 -1035 -1085
Note 3: F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals -55°C), then testing immediately without allowing for the junction temperature to stabilize due to heat dissipation after power-up. This provides "cold start" specs which can be considered a worst case condition at cold temperatures. Note 4: Screen tested 100% on each device at -55°C, +25°C, and +125°C, Subgroups 1, 2, 3, 7, and 8. Note 5: Sample tested (Method 5005, Table I) on each manufactured lot at -55°C, +25°C, and +125°C, Subgroups A1, 2, 3, 7, and 8. Note 6: Guaranteed by applying specified input condition and testing VOH/VOL.
AC Electrical Characteristics
VEE = -4.2V to -5.7V, VCC = VCCA = GND Symbol tPLH tPHL tPLH tPHL tTLH tTHL Parameter Propagation Delay Data to Output Propagation Delay Enable to Output Transition Time 20% to 80%, 80% to 20% 0.30 1.20 0.30 1.20 0.30 1.20 ns 0.60 2.60 0.80 2.30 0.80 2.80 ns TC = -55°C Min 0.30 Max 1.80 TC = +25°C Min 0.40 Max 1.50 TC = +125°C Min 0.40 Max 1.70 ns (Notes 7, 8, 9, 10, 11) Units Conditions Notes
Figures 1, 2
(Note 10)
Note 7: F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals -55°C), then testing immediately after power-up. This provides "cold start" specs which can be considered a worst case condition at cold temperatures.
3
www.national.com
AC Electrical Characteristics
(Continued)
Note 8: Screen tested 100% on each device at +25°C temperature only, Subgroup A9. Note 9: Sample tested (Method 5005, Table I) on each manufactured lot at +25°C, Subgroup A9, and at +125°C and -55°C temperatures, Subgroups A10 and A11. Note 10: Not tested at +25°C, +125°C, and -55°C temperature (design characterization data). Note 11: The propagation delay specified is for single output switching. Delays may vary up to 100 ps with multiple outputs switching.
Test Circuitry
DS100303-5
Notes: VCC, VCCA = +2V, VEE = -2.5V L1 and L2 = equal length 50 impedance lines RT = 50 terminator internal to scope Decoupling 0.1 µF from GND to VCC and VEE All unused outputs are loaded with 50 to GND CL = Fixture and stray capacitance 3 pF
FIGURE 1. AC Test Circuit
Switching Waveforms
DS100303-6
FIGURE 2. Propagation Delay and Transition Times
www.national.com
4
Physical Dimensions
inches (millimeters) unless otherwise noted
24-Lead Ceramic Dual-In-Line Package (0.400" Wide) (D) NS Package Number J24E
24-Lead Quad Cerpak (F) NS Package Number W24B
5
www.national.com
|
|