Details, datasheet, quote on part number:130MT080KB
| |
| Part: | 130MT080KB |
| Category: | Power Management => AC-DC Controllers/Converters => Bridge Rectifiers |
| Description: | Three Phase Bridge Mt..kb Series Power Modules |
| Company: | International Rectifier Corp. |
| Datasheet: | Download 130MT080KB datasheet File size : 75 kB |
| Request For quote: | Find where to buy 130MT080KB
|
| |
Datasheet text preview:
Bulletin I27502 08/97
MT..KB SERIES
THREE PHASE BRIDGE Features
Package fully compatible with the industry standard INT-A-pak power modules series High thermal conductivity package, electrically insulated case Outstanding number of power encapsulated components Excellent power volume ratio, outline for easy connections to power transistor and IGBT modules 4000 VRMS isolating voltage UL E78996 approved
Power Modules
130 A 160 A
Description
A range of extremely compact, encapsulated three phase b r i d g e rectifiers offering efficient and reliable operation. T h e y are intended for use in general purpose and heavy d u t y applications.
Major Ratings and Characteristics
Parameters
IO @ TC IFSM I2t @ 50Hz @ 60Hz @ 50Hz @ 60Hz I2 t VRRM TSTG TJ range range range
130MT.KB 160MT.KB
130 (160) 85 (62) 1130 1180 6400 5800 64000 160 (200) 85 (60) 1430 1500 10200 9300 102000
Units
A °C A A A2s A2 s A2 s V °C °C
800 to 1600 - 40 to 150 - 40 to 150
www.irf.com
1
130-160MT..KB Series
Bulletin I27502 08/97
ELECTRICAL SPECIFICATIONS Voltage Ratings
Type number Voltage Code
80 100 130-160MT..KB 120 140 160
V RRM , maximum repetitive peak reverse voltage V
800 1000 1200 1400 1600
VRSM , maximum nonrepetitive peak rev. voltage V
900 1100 1300 1500 1700
I RRM max.
@ TJ max.
mA
10
Forward Conduction
Parameter
IO IFSM Maximum DC output current @ Case temperature Maximum peak, one-cycle forward, non-repetitive surge current
130MT.KB 160MT.KB Units Conditions
130 (160) 85 (62) 1130 1180 950 1000 160 (200) 85 (60) 1430 1500 1200 1260 10200 9300 7200 6600 102000 0.81 1.04 3.52 3.13 1.49 4000 V V m A2 s V A2 s A °C A t = 10ms t = 8.3ms t = 10ms t = 8.3ms t = 10ms t = 8.3ms t = 10ms t = 8.3ms No voltage reapplied 1 0 0 % VR R M reapplied No voltage reapplied 1 0 0 % VR R M reapplied Initial TJ = TJ max. 120° Rect conduction angle
I2 t
Maximum I2 t for fusing
64000 5800 4500 4100
I2 t
Maximum I2 t for fusing
64000 0.78 0.99 4.59 4.17 1.63 4000
t = 0.1 to 10ms, no voltage reapplied (16.7% x x IF(AV) x IF(AV)), @ T J max. (16.7% x x IF(AV) x IF(AV)), @ T J max. Ipk = 200A, TJ = 25°C, tp = 400µs single junction TJ = 25°C, all terminal shorted f = 50Hz, t = 1s
VF(TO)1 Low level value of threshold voltage VF(TO)2 High level value of threshold voltage rf1 rf2 VFM VINS Low level value of forward slope resistance High level value of forward slope resistance Maximum forward voltage drop RMS isolation voltage
Thermal and Mechanical Specifications
Parameter
TJ Tstg RthJC Max. junction operating temperature range Max. storage temperature range Max. thermal resistance, junction to case
130MT.KB 160MT.KB Units Conditions
-40 to 150 -40 to 150 0.16 0.93 0.18 1.08 0.12 0.73 0.15 0.88 0.03 K/ W °C °C K/W DC operation per module DC operation per junction 120° Rect condunction angle per module 120° Rect condunction angle per junction Per module Mounting surface smooth, flat and greased
A mounting compound is recommended and the torque should be rechecked after a period of 3 hours to allow for the spread of the compound. Lubricated threads.
RthCS Max. thermal resistance, case to heatsink T Mounting torque ± 10% to heatsink to terminal wt Approximate weight
4 to 6 3 to 4 225
Nm
g
2
www.irf.com
130-160MT..KB Series
Bulletin I27502 08/97
Ordering Information Table
Device Code
16
1 1 -
0
2
MT
3
160
4
K
B
5
Current rating code: 13 = 130 A (Avg) 16 = 160 A (Avg)
2 3 4 5
-
Three phase diodes bridge Essential part number Voltage code: Code x 10 = VRRM (See Voltage Ratings Table) Generation II
Outline Table (without optional barriers)
D A B C E F
All dimensions in millimeters (inches)
NOTE: To order the Optional Hardware see Bulletin I27900
www.irf.com 3
130-160MT..KB Series
Bulletin I27502 08/97
Outline Table (with optional barriers)
D A B C E F
All dimensions in millimeters (inches)
Maximum Allowable Case Temperature (°C)
150 130MT..KB Series 130 120 110 100 90 80 70 60 50 0 20 40 60 80 100 120 140 160 180 Total Output Current (A) 120° (Rect)
Instantaneous Forward Current (A)
1000
140
100
T = 25°C J 10 T = 150°C J
130MT..KB Series Per Junction 1 0 1 2 3 4 5 Instantaneous Forward Voltage (V)
Fig. 1 - Current Ratings Characteristics
Fig. 2 - Forward Voltage Drop Characteristics
4
www.irf.com
130-160MT..KB Series
Bulletin I27502 08/97
500 450 Maximum Total Power Loss (W) 400 350 300 250 200 150 100 50 0 0 20 40 60 80 100 120 140 160 0 25 50 75 100 125 150 Total Output Current (A) Maxi mum Allowable Ambient Temperature (°C)
0.5 K/W 0.7 K/W
130MT..KB Series T = 150°C J 120° (Rect)
R th
0. 12
0.2
K/ W
SA
= 05 0. W K/
K/ W 0.3 K/W
ta el -D R
1.5 K/ W
Fig. 3 - Total Power Loss Characteristics
1000 900 800 700 600 500 400 300 200 1 10 100
Number Of Equal Am litude Half Cycle Current Pulses (N) p
Peak Half Sine W ve Forward Current (A) a
At Any Rated Load Condition And With Rated VRRM Applied Following Surge. Initial TJ = 150°C @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s
Peak Half Sine Wave Forward Current (A)
1200 1100 1000 900 800 700 600 500 400 300 200 0.01
Maxi mum Non Repetitive Surge Current Versus Pulse Train Duration. Initi al TJ = 150°C No Voltage Reapplied Rated VRRMReapplied
130MT..KB Series
130MT..KB Series
0.1 Pulse Train Duration (s)
1
Fig. 4 - Maximum Non-Repetitive Surge Current
150 160MT..KB Series 140 130 120 110 100 90 80 70 60 50 0 40 80 120 160 200 240 Total Output Current (A) 120° (Rect)
Instantaneous Forward Current (A)
Fig. 5 - Maximum Non-Repetitive Surge Current
1000
Maximum Allowable Case Temperature (°C)
100
T = 25°C J 10 T = 150°C J
160MT..KB Series Per Junction 1 0 1 2 3 4 5 Instantaneous Forward Voltage (V)
Fig. 6 - Current Ratings Characteristics
Fig. 7 - Forward Voltage Drop Characteristics
www.irf.com
5
|
|