Datasheet text preview:
R
F10 Vision Sensor
Affordable F10 Vision Sensor with One-Touch Setup Requires No Programming H Ensures fast, accurate inspections such
as label pattern match, print verification, label placement, and conformity (rejects upside-down, tilted or double labels)
F10
H Offers adaptability with 3 selectable
inspection areas
H F10 Sensor includes a controller,
camera, light source, and light guide
Ordering Information
J PATTERN MATCHING AMPLIFIER
Item F10-C10/-C15 Pattern Matching Amplifier Description Pattern measurement Output type NPN Part number F10-C10
PNP
F10-C15
F10-C11/-C16 Pattern Matching Amplifier
Pattern measurement only, or selectable pattern and plain measurement
NPN
F10-C11
PNP
F10-C16
F10
J HEAD
Item F10-S30 Head Sensing area 25 mm x 20 mm (0.98 in x 0.79 in) Setting distance 100 ± 10 mm (3.94 ± 0.39 in) Part number F10-S30
F10
F10-S15 Head
12 mm x 10 mm (0.47 in x 0.39 in)
50 ± 5 mm (1.96 in x 0.20 in)
F10-S15
Specifications
J PERFORMANCE SPECIFICATIONS -- F10-C10/-C15 AMPLIFIERS
Item Output type Measurement item Number of models Automatic teaching function Model size Measurement processing time Output signal (2 points)
F10-C10 NPN Pattern measurement 1 Yes Normal or wide mode (selectable)
F10-C15 PNP
3.6 ms in normal mode and 10.8 ms in wide mode (continuous operation) Control output and enable output: NPN open collector with load current of 50 mA max. and residual voltage of 1.2 V max. External trigger input (with minimum pulse width of 1 ms), continuous measurement input, moving object teaching input, or stationary object teaching input. Input is ON: Short-circuited to 0 V with short-circuit current of 1 mA max. or 1.5 V max. Input is OFF: Open or input voltage of 5 V min. (Max. input voltage: 26.4 VDC) Available Head: F10-S30 or F10-S15 Result indicator: 1 orange LED Level indicators: 8 green LEDs Threshold indicators: 7 red LEDs Teaching button (TEACH), SELECT buttons (UP/DOWN), mode selector (TEACH/MON/RUN), auto-teaching selector (OFF/ON), and model size selector (NORMAL/WIDE) Control output and enable output: PNP open collector with load current of 50 mA max. and residual voltage of 2.0 V max. External trigger input (with minimum pulse width of 1 ms), continuous measurement input, moving object teaching input, or stationary object teaching input. Input is ON: Short-circuited to Vcc or 9 V min. with max. input voltage of 26.4 VDC. Input is OFF: Open or input voltage of 5 V max.
Input signal (4 points)
Head interface (1 channel) Indicators
Operation interface
2
F10
J PERFORMANCE SPECIFICATIONS -- F10-C11/-C16 AMPLIFIERS
F10
Item Output type Measurement item Number of models Automatic teaching function Model size Measurement processing time Output signal (2 points)
F10-C11 NPN 1 Yes
F10-C16 PNP
Pattern measurement only or pattern or plain measurement (selectable)
Normal or wide mode (selectable), disabled in plain measurement operation Pattern measurement: 3.6 ms in normal mode and 10.8 ms in wide mode (continuous operation) Plain measurement: 7.2 ms in continuous operation Control output and enable output: NPN open collector with load current of 50 mA max. and residual voltage of 1.2 V max. External trigger input (with minimum pulse width of 1 ms), continuous measurement input, moving object teaching input, or stationary object teaching input. Input is ON: Short-circuited to 0 V with short-circuit current of 1 mA max. or 1.5 V max. Input is OFF: Open or input voltage of 5 V min. (Max. input voltage: 26.4 VDC) Available Head: F10-S30 or F10-S15 Result indicator: 1 orange LED Level indicators: 8 green LEDs Threshold indicators: 7 red LEDs Status indicators: 3 green LEDs Teaching and display button (TEACH/DISPLAY), SELECT buttons (UP/DOWN), measurement item selector (PATT/PLN or PATT), mode selector (TEACH/MON/RUN), auto-teaching selector (OFF/ON), and model size selector (NORMAL/WIDE) Control output and enable output: PNP open collector with load current of 50 mA max. and residual voltage of 2.0 V max. External trigger input (with minimum pulse width of 1 ms), continuous measurement input, moving object teaching input, or stationary object teaching input. Input is ON: Short-circuited to Vcc or 9 V min. with max. input voltage of 26.4 VDC. Input is OFF: Open or input voltage of 5 V max.
Input signal (4 points)
Head interface (1 channel) Indicators
Operation interface
J GENERAL SPECIFICATIONS -- F10-C10/-C15 OR F10-C11/-C16 AMPLIFIERS
Operating temperature Operating humidity Storage temperature Operating environment Input power supply Current consumption Insulation resistance Dielectric strength Degree of protection Vibration resistance Shock resistance Cable length Casing material Weight 0°C to 50°C (32°F to 122°F) 35% to 85% (with no condensation) 25°C to 65°C (13°F to 149°F) with no icing With no corrosive gas 24 VDC ± 10% (with ripple) 300 mA max. 20 M min. (at 500 VDC) 1,000 VAC at 50/60 Hz for 1 min IEC60529 IP40 10 to 150 Hz, 0.75-mm single amplitude or 100 m/s2 (10G) max. for 32 min each in X, Y, and Z directions Peak acceleration: 300 m/s2 (30G) 3 times each in X, Y, and Z directions 2m ABS Approx. 200 g (including cable)
Note: An F10-C10/-C15 or F10-C11/-C16 Amplifier connects to one F10-S30 or F10-S15 Head. Teach and threshold level adjustments will be required again if the Head is replaced.
3
F10
J HEADS
Optical and Lighting System Specifications
Item Appearance F10-S30 F10-S15
F10
Sensing distance Sensing area Guide light projection size
100 ± 10 mm 25 mm x 20 mm A: 25 mm (0.98 in) B: 20 mm (0.79 in) C: 8 mm (0.31 in) D: 6 mm (0.24 in) E: 20 mm (0.79 in)
50 ± 5 mm 12 mm x 10 mm A: 12 mm (0.47 in) B: 10 mm (0.39 in) C: 4 mm (0.16 in) D: 3 mm (0.12 in) E: 10 mm (0.39 in)
Built-in lens Object lighting method Object light source Main object color combination
Focus: f9.8 (fixed) Diaphragm: F2.8 (fixed) Pulse lighting (pulse width is synchronized with electronic shutter in operation) 8 red LEDs Black and white, green and white, blue and white, and red and black 1 green LED Pulse lighting 8 green LEDs Black and white, red and white, green and white, blue and white, green and black, and blue and black 1 blue LED
Guide light projection source Guide light projection method
Camera Image Performance Specification
Item Camera image element Shutter function F10-S30 1/5-inch CCD Electronic shutter at a speed range between 1/34722 and 1/2894 s (automatically set during teaching) F10-S15
4
F10
J GENERAL SPECIFICATIONS -- F10-S30/-S15 HEADS
Operating temperature Operating humidity Storage temperature Operating environment Input power supply Current consumption Insulation resistance Dielectric strength Degree of protection Vibration resistance (with mounting bracket attached) Shock resistance (with mounting bracket attached) Cable length Casing material Weight Accessories provided 0°C to 40°C (32°F to 104°F) 35% to 85% (with no condensation) 25°C to 60°C (13°F to 140°F) with no icing With no corrosive gas 18 VDC ± 10% (provided from amplifier) 150 mA max. 20 M min. (at 500 VDC) 1,000 VAC at 50/60 Hz for 1 min IEC60529 IP64
F10
10 to 150 Hz, 0.75-mm single amplitude or 100 m/s2 (10G) max. for 32 min each in X, Y, and Z directions Peak acceleration: 300 m/s2 (30G) 3 times each in X, Y, and Z directions 2m Case: Aluminum die cast Front cover: Acrylic resin Approx. 300 g (including cable) A dedicated mounting bracket, two M4 screws, and two M4 washers
Application Examples
J F10-C11/-C16 AMPLIFIER
Measures Plain Objects Without Colors or Patterns
Each object is discriminated according to the deviation and average density. A plain object without colors or patterns will be detected if a sample of the plain object is registered as a model by teaching. Plain without colors or patterns Color Stain Pattern
Teaching
Discriminates Improper Objects
Plain or pattern measurement is applicable to the discrimination of improper objects. If a sample of a plain or patterned object is registered as a model by teaching, the Sensor will operate and automatically detect objects identical to the model. Pattern measurement Pattern measurement Plain measurement
5
|
|