Details, datasheet, quote on part number: RM1A23D25
PartRM1A23D25
Category
TitleRELAY SSR 25A 32VDC IN
Description
CompanyCARLO GAVAZZI
DatasheetDownload RM1A23D25 datasheet
Cross ref.Similar parts: CWD2425
Quote
Find where to buy
 
  
RM1A23D25 photo

Others parts numbering
RM1A23D50: RELAY SSR 50A 32VDC IN
RM1A48D25: RELAY SSR 25A 480V
RM1A48D50: RELAY SSR 50A 480V
RM1A48A50
RM1A60D50: RELAY SSR 50A 600V
RM1A60A50
RM1A48D75: RELAY SSR 75A 480V
RM1A48A75
RM1A48D100: RELAY SSR 100A 480V
RM1A60D100: RELAY SSR 100A 600V
RM1A60A100
RM1A23A25: RELAY SSR 25A 280VAC IN
RM1A23A50: RELAY SSR 50A 280VAC IN
RM1A48A25: RELAY SSR 25A 480V
RM1A23D75: RELAY SSR 75A 32VDC IN
RM1A23A75: RELAY SSR 75A 280VAC IN

 

Features, Applications
Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 60

Zero switching (RM1A) or instant-on switching (RM1B) AC Solid State Relay Direct copper bonding (DCB) technology LED indication Built-in varistor Clip-on IP 20 protection cover Self-lifting terminals Housing free of moulding mass 2 input ranges: 3-32* VDC and 20-280VAC/22-48VDC Operational ratings: to 100AACrms and 600VACrms Blocking voltage: to 1400Vp Opto-isolation: > 4000VACrms CE, RoHS compliant cURus, CSA, CCC

The industrial, 1-phase relay with antiparallel thyristor output is the most widely used industrial SSR due to its multiple application possibilities. The relay can be used for resistive, inductive and capacitive loads. The zero switching relay switches ON when the sinusoidal curve crosses zero and switches OFF when the current crosses zero. The instant-on relay with DC control input can be used for phase control. The built-in varistor secures transient protection for the heavy industrial applications, and the LED indicates the status of the control input. The clipon cover is securing touch protection IP 20. Protected output terminals can handle cables to 16mm2.

Solid State Relay Number of poles Switching mode Rated operational voltage Control voltage Rated operational current

Switching mode A: Zero Switching B: Instant-on switching (DC Control only)

RM1.23... Operational voltage range RM1A... RM1B... Blocking voltage Zero voltage turn-on Operational frequency range Power factor Approvals CE-marking Isolation Input to Output input and Output to case RM1.48... RM1.60...

RM1...D.. Control voltage range RM1A60... RM1B... Pick-up voltage RM1A60... RM1B... Reverse voltage Drop out voltage Input current @ max input voltage RM1A RM1B Response time pick-up RM1A RM1B Response time drop-out

RM1....25 Rated operational current @ Ta=25C Min. operational current Rep. overload current t=1 s Non-rep. surge current t=10 ms Off-state leakage current @ rated voltage and frequency I2t for fusing t=10 ms On-state voltage drop @ rated current Critical dV/dt off-state min. Endurance testing acc. s 100,000 cycles

Note: UL requirement for General Use Endurance testing is 6,000 cycles

EMC Immunity Electrostatic Discharge (ESD) Immunity Air discharge, 8kV Contact, 4kV Electrical Fast Transient (Burst) Immunity Output: 2kV, 5kHz Input: 1kV, 5kHz Electrical Surge Immunity Output, line to line, 1kV Output, line to earth, 2kV Input, line to line, 1kV Input, line to earth, 2kV IEC/EN 61000-6-2 IEC/EN 61000-4-2 Performance Criteria 2 Performance Criteria 2 IEC/EN 61000-4-4 Performance Criteria 1 Performance Criteria 1 IEC/EN 61000-4-5 Performance Criteria 2 Performance Criteria 2 Performance Criteria 2 Performance Criteria 2 Radiated Radio Frequency Immunity - 1000 MHz 2.0GHz 3 V/m, - 2.7GHz Conducted Radio Frequency Immunity - 80 MHz Voltage Dips Immunity 0% for / 1 cycle 40% for 10 cycles 70% for 25 cycles Voltage Interruptions Immunity 0% for 5000ms IEC/EN 61000-4-3 Performance Criteria 1 Performance Criteria 1 Performance Criteria 1 IEC/EN 61000-4-6 Performance Criteria 1 IEC/EN 61000-4-11 Performance Criteria 2 Performance Criteria 2 Performance Criteria 2 IEC/EN 61000-4-11 Performance Criteria 2

EMC Emission Radio Interference Voltage Emission (Conducted) - 30MHz

IEC/EN 61000-6-4 IEC/EN 55011 Class A (industrial) with filters IEC/EN 60947-4-3 Class A (no filtering needed to 75AAC)

Notes: - Control input lines must be installed together to maintain products' susceptibility to Radio Frequency interference. - Performance Criteria 1: No degradation of performance or loss of function is allowed when the product is operated as intended. - Performance Criteria 2: During the test, degradation of performance or partial loss of function is allowed. However, when the test is complete the product should return operating as intended by itself. - Performance Criteria 3: Temporary loss of function is allowed, provided the function can be restored by manual operation of the controls.


 

Some Part number from the same manufacture CARLO GAVAZZI
RM1A23D50
RM1A48D25
RM1A48D50
RM1A48A50
RM1A60D50
RM1A60A50
RM1A48D75
RM1A48A75
RM1A48D100
RM1A60D100
RM1A60A100
RM1A23A25
RM1A23A50
RM1A48A25
RM1A23D75
RM1A23A75
CC50SA120
CC9SA120
CC12SA120
CC18SA120
CC22SA120
 
0-C     D-L     M-R     S-Z